Search found 3 matches

by juancri
Tue Jun 21, 2011 12:33 am
Forum: Inetlab.SMPP v1.0
Topic: NeedEnquireLink on server
Replies: 1
Views: 6251

NeedEnquireLink on server

Hi: I created a small server using this code: var server = new SmppServer (); server.evClientConnected += ((sender, client) => { client.EnquireInterval = 30; client.NeedEnquireLink = true; }); server.StartAsync (9876); The problem is that the enquire link command is not sent. This works if configure...
by juancri
Thu Mar 17, 2011 3:59 am
Forum: Inetlab.SMPP v1.0
Topic: Password length
Replies: 1
Views: 5304

Re: Password length

Oh, now I see this note in the specs (page 36): In the case of all C-Octet String formats, the maximum field size is shown as a combination of string length and the NULL terminator, i.e., an 8-character C-Octet String is encoded in 9 octets when the NULL terminator is included. So I think the origin...
by juancri
Wed Mar 16, 2011 4:09 pm
Forum: Inetlab.SMPP v1.0
Topic: Password length
Replies: 1
Views: 5304

Password length

Hi: I have been using the library and there's a problem in the file src/CS/PDU/Bind.cs This: if(s.Length > 8) { throw new System.ArgumentOutOfRangeException("Password","Length too long"); } Should be replaced with with: if(s.Length > 9) { throw new System.ArgumentOutOfRangeException("Password","Leng...